Show simple item record

Resistencia a la compresión de Biodentine®: mezcla manual vs. Mecánica

dc.contributor.authorMolina, Gustavo F.
dc.contributor.authorUlfohn, Javier
dc.contributor.authorArce Brissón, Georgette
dc.contributor.authorBoetto, Cecilia
dc.contributor.authorMazzola, Ignacio
dc.contributor.authorBrain Lascano, Laura
dc.contributor.authorZaya, Luis M.
dc.contributor.authorSainz Aja, Martin
dc.contributor.authorPascualini, Carlos J.
dc.contributor.authorFarah, Martín
dc.contributor.authorFarah, Miguel
dc.contributor.authorCabral, Ricardo J.
dc.date.accessioned2024-03-13T15:10:09Z
dc.date.available2024-03-13T15:10:09Z
dc.date.issued2021
dc.identifier.issn2545-8302
dc.identifier.urihttp://hdl.handle.net/11086/551041
dc.description.abstractLa incorporación de innovaciones tecnológicas en determinados materiales dentales, especialmente aquellos que requieren de aparatología específica para su uso y/o cuya pre-dosificación implica el descarte de una porción de su contenido, está condicionada por la relación costo-beneficio del producto. Según las instrucciones del fabricante, las cápsulas del silicato tricálcico Biodentine® (Septodont) deben activarse mediante el uso de mezcladores mecánicos luego de adicionar las proporciones exactas del líquido ad-hoc, utilizando la totalidad de cada cápsula de polvo y su respectiva ampolla del líquido, con un excedente de material considerable, según su indicación. Si bien es posible realizar la mezcla del cemento en forma manual prescindiendo de un amalgamador, una modificación en las recomendaciones del fabricante podría alterar las propiedades del material.OBJETIVO: Determinar si existen diferencias en la resistencia compresiva de Biodentine® según el método de mezcla utilizado: con activación mecánica y con mezcla manual.MATERIALES Y METODOS: Se confeccionaron probetas cilíndricas de 6 mm de alto por 4 mm de diámetro (n=6) para los dos grupos de estudio A) Biodentine® / Mezcla manual y B) Biodentine® / Mezcla mecánica. Las muestras fueron sometidas a la aplicación de una fuerza continua en máquina universal de ensayos Digimess RS-8000-5 a una velocidad de carrera de 1 mm/min hasta su ruptura. Se compararon los valores obtenidos entre los grupos mediante test de Student, determinando diferencias significativas para valores de p>0,05.RESULTADOS: Los valores medios obtenidos y su desviación estándar fueron A) 52.6 (16.3) MPa y B) 65.7 (30.6) MPa respectivamente. La distribución de valores de resistencia a la compresión según el grupo de estudio fue levemente superior en el grupo B, aunque las diferencias no fueron significativas (p=3,77). CONCLUSIONES: La mezcla manual no disminuye significativamente la resistencia a la compresión de Biodentine® en comparación al cemento mezclado mecánicamente.es
dc.description.abstractEconomic circumstances may create difficulties in access to certain dental materials, especially those that a part of their content has to be disposed after mixing. According to the manufacturers´ instructions, capsules of tri-calcium silicate Biodentine® (Septodont) ought to be activated using a mechanical mixer after addition of the liquid accordingly. The whole content of a capsule is then used before the setting of the material. Aim: To compare the effect of the mixing mode on the compressive strength of Biodentine®, mixed manually and using a mechanical mixer. OBJECTIVE: To compare the effect of the mixing mode on the compressive strength of Biodentine®, mixed manually and using a mechanical mixer. MATERIALS AND METHODS Two groups were defined, A) Biodentine® / Manual mix and B) Biodentine® / Mechanical mix, with n = 6 cylindric specimens each of 6 mm height and 4 mm diameter. Samples were tested using a universal testing machine Digimess RS-8000-5 at a crosshead speed of 1 mm/min until fracture. Obtained values were compared using the Student-t test with a significance of p>0,05. RESULTS: Mean values were A) 52.6 (16.3) MPa and B) 65.7 (30.6) MPa respectively, finding no significant differences between the two groups (p=3,77). CONCLUSION: Compressive strength is not affected in Biodentine® when mixed manually compared to mechanical mixing.
dc.description.urihttps://methodo.ucc.edu.ar/index.php/methodo/about
dc.format.mediumDigital
dc.language.isospaes
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectCementos dentaleses
dc.subjectSilicatos
dc.subjectComportamiento físico
dc.subjectDental Cements
dc.subjectPhysical Performance
dc.subjectSilicates
dc.titleCompressive strength of Biodentine®: mechanical vs. manual mixes
dc.titleResistencia a la compresión de Biodentine®: mezcla manual vs. Mecánica
dc.typearticlees
dc.description.versionpublishedVersion
dc.description.filFil: Molina, Gustavo F. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Ulfohn, Javier. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Arce Brissón, Georgette. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Endodoncia; Argentina.
dc.description.filFil: Boetto, Cecilia. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Endodoncia; Argentina.
dc.description.filFil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Brain Lascano, Laura. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Zaya, Luis M. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Sainz Aja, Martin. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Pascualini, Carlos J. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Farah, Martín. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Farah, Miguel. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.description.filFil: Cabral, Ricardo J. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
dc.journal.cityCórdoba
dc.journal.countryArgentina
dc.journal.editorialUniversidad Católica de Córdoba
dc.journal.referatoCon referato
dc.journal.titleMethodo
dc.description.fieldOtras Biotecnologías de la Salud


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 4.0 International
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 4.0 International